Oil immersed transformer is a widely used distribution and power transformer that uses insulating oil as cooling and dielectric medium. Thanks to stable performance, low manufacturing cost and strong overload capacity, it remains the preferred solution for power grids, photovoltaic power stations, industrial parks, mining and remote power supply projects worldwide.
With 15 years of manufacturing experience, Xinhong Electrical produces oil immersed transformers ranging from 100kVA to 25MVA, 6kV–35kV. All units adopt pure copper windings and strictly follow IEC 60076 standards. Our products carry CE, ISO and CB certifications and have been exported to Southeast Asia, Africa, Central Asia and other overseas markets.
The core cooling medium of an oil immersed transformer is mineral insulating oil. During operation, heat generated by windings and iron core transfers to the oil. Hot oil rises and circulates through radiators, dissipating heat into the air. After cooling down, the oil flows back to the tank, forming a natural circulation cooling loop.
The insulating oil serves two key functions:
Optional cooling types: ONAN (natural oil natural air), ONAF (natural oil forced air) for higher load demands.
✅ High overload capability, suitable for fluctuating load such as solar and wind power
✅ Long service life under proper maintenance, normally 25–30 years
✅ Lower unit cost compared with dry type transformer at the same capacity
✅ Excellent heat dissipation for large capacity above 2500kVA
✅ Robust structure, adapt to outdoor harsh environment
✅ Easy on-site repair and spare parts replacement
Many buyers struggle to choose between oil immersed transformer and dry transformer. Here is a simple comparison for your reference:
Xinhong Electrical owns a 27,000 ㎡ factory in Jiangsu, China. We support standard production and customized design for special voltage, vector group, protection configuration.
For normal grid operation, annual oil dielectric strength test is recommended. For critical PV and mining projects, test every 6 months.
Yes, but you must prepare an oil containment pit, ventilation system and fire prevention measures according to local electrical codes.
ONAN means natural cooling without fan. ONAF adds cooling fans to increase continuous load capacity by about 30%–40%.
Yes, we can configure Dyn11, YNd11 and other vector groups, with off-circuit or on-load tap changer as requested.
Send us your requirements including rated capacity, primary & secondary voltage, cooling type, quantity and target market standard. Our engineering team will reply with formal quotation and datasheet quickly.