Oil immersed transformer is the most widely adopted power transformer for power grid, solar/wind boost station, industrial park and mining projects globally. Compared with dry type transformers, oil immersed transformers feature lower cost, better heat dissipation, higher overload capacity and longer service life, which makes it the preferred solution for medium and large power distribution systems.
Xinhong Electrical is a professional Chinese manufacturer with 15 years export experience. Our oil immersed transformers adopt pure copper winding, strictly designed and tested per IEC 60076 standard, available with CE, ISO and CB certifications. We supply units from 100kVA to 25MVA for clients in Africa, Southeast Asia, Central Asia and the Middle East.
An oil immersed transformer is a transformer whose core and windings are submerged in insulating mineral oil. The transformer oil works as both insulation medium and heat transfer medium. Heat generated during operation is transferred to the tank surface and radiated into ambient air.
Common cooling modes include ONAN (Oil Natural Air Natural) and ONAF (Oil Natural Air Forced). It is mainly used for outdoor installation, substation, solar booster station and heavy-duty industrial load.
All our oil immersed transformers comply with IEC 60076 series standards, including routine tests, type tests and special tests as required. We can also adjust design to meet local grid requirements for different countries. Certifications including CE, ISO 9001, CB test reports are available for tender submission and inspection.
This is the most frequent question raised by EPC engineers and project buyers.
Following IEC 60076 requirements, every oil immersed transformer will finish routine tests before shipment:
Type tests including temperature rise test, lightning impulse test and short-circuit withstand test are available on request for tender projects.
A: Yes, but fire prevention and oil collection pit are mandatory according to local electrical codes. Most clients prefer dry type transformers for indoor crowded public areas.
A: Normally DGA (dissolved gas analysis) test once per year for grid transformers. For solar farm transformers, oil testing every 12–24 months is recommended.
A: ONAN means natural cooling without fan; ONAF uses cooling fans to enhance heat dissipation, supporting higher continuous loading capacity.
A: Yes, our engineering team supports custom design for voltage ratio, vector group and accessories according to your project specification.
We are a direct factory located in Jiangsu, China, with 27000㎡ production workshop. All our copper winding oil immersed transformers are built under IEC 60076 and fully inspected before shipment.
Send your capacity, voltage, cooling method and project location to our sales team. We will offer technical datasheet, test plan and formal quotation for your power project.