An 11kV dry transformer (cast resin dry type transformer) is a medium-voltage power transformer that steps down 11kV high voltage to low voltage such as 400V, 415V or 690V, using epoxy resin solid insulation and air cooling instead of transformer oil. As a professional dry transformer china manufacturer, Xinhong Electrical supplies 11kV dry type transformers for global industrial, commercial and renewable energy projects, fully compliant with IEC 60076, ISO, CE and CB standards.
Unlike oil immersed transformers, the 11kV dry transformer eliminates flammable insulating liquid, so it carries much lower fire risk and no oil leakage pollution. It is the preferred solution for indoor substations and sites with strict fire and environmental requirements.
Below are standard parameters for Xinhong Electrical 11kV cast resin dry transformers. Customized design is available for special project requirements.
Optional accessories: temperature controller, PT100 sensors, alarm system, ventilation fans, shock pads, anti-condensation heater.
The 11kV dry transformer is widely used where safety, low maintenance and environmental protection are mandatory.
For high-density indoor installation, cast resin dry transformers from Xinhong Electrical are self-extinguishing, dust-resistant and moisture-resistant, greatly reducing routine maintenance work compared with oil transformers.
Many buyers ask for the price of 11kV dry transformer, but there is no fixed unit price. Xinhong Electrical, China factory, lists the main cost factors for your reference:
Choosing the right dry type transformer avoids overload risk, extra energy loss and project rework. Follow these key points:
Make sure the primary 11kV matches your local utility grid. Confirm secondary voltage for your load: 400V for most common distribution, 690V for heavy industrial or solar projects.
Pure copper winding is our standard supply at Xinhong Electrical. It has lower no-load & load loss, better heat dissipation and longer service life. Aluminum winding is available only for budget-sensitive projects with clear loss acceptance.
For export projects, confirm whether you need CE, CB, IEC test report. As a China factory with 15 years experience, Xinhong Electrical can provide full certification documents for tender and customs clearance.
We suggest selecting transformer capacity with 15%~25% spare margin for future equipment expansion, to avoid frequent overload and overheating.
Xinhong Electrical is a professional dry transformer china manufacturer based in Jiangsu, China, with a 27,000㎡ factory and 15 years of production experience on dry transformers, oil immersed transformers and box substations.
✅ Pure copper winding, low loss, high efficiency
✅ ISO9001, ISO14001, ISO45001, CE, CB, IEC 60076 certified
✅ Support customized voltage, capacity, IP grade and accessories
✅ Strict routine test and partial discharge test before delivery
✅ Flexible trade terms: EXW, FOB, CIF, DAP available
✅ Technical support, installation guidance and long-term after-sales service
Dry transformer wins on fire safety, zero leakage and low maintenance for indoor space. Oil immersed transformer is usually cheaper for large outdoor utility substations with enough fire separation space.
Yes, but you need an IP54 enclosure plus anti-condensation heater and rainproof canopy. Standard IP23 dry transformers are for indoor use only.
Under normal load and clean ventilation environment, Xinhong Electrical 11kV dry transformers can run 25–30 years with simple maintenance.
If you are sourcing 11kV dry transformer for your project, send us your technical parameters, site condition and required certification. Xinhong Electrical’s engineering team will offer you a suitable solution and competitive factory price from China.
Contact Xinhong Electrical today for cast resin dry transformer drawings, test reports and quotation.