Категории

Solid Insulated Ring Main Unit: Electrical Parameters, Insulation Structure & Operation Conditions | Xinhong Electrical

Learn solid insulated RMU key electrical parameters, epoxy insulation structure and O&M adaptability. Xinhong Electrical is a reliable China‑based medium‑voltage switchgear manufacturer complying with IEC & ISO standards. Get your technical solution today.
Sep 8th,2026 13 Взгляды
Solid Insulated Ring Main Unit: Electrical Parameters, Insulation Structure and O&M Adaptation Conditions

Beneath the global trend of grid modernization and SF₆‑free power equipment transition, solid insulated ring main unit (solid insulated RMU) has become a mainstream medium‑voltage switchgear choice for urban distribution networks, industrial parks, mining sites and harsh‑environment projects. As a professional China‑based medium‑voltage switchgear manufacturer, Xinhong Electrical delivers standardized and customized solid insulated RMU complying with IEC60076, ISO and CE certification requirements. This article elaborates core electrical parameters, insulation structure features and operation‑maintenance adapt conditions to support your project selection and site deployment.

1. Core Electrical Parameters of Solid Insulated Ring Main Unit

Solid insulated RMU covers 12kV‑24kV medium‑voltage class, widely used in 50Hz / 60Hz AC three‑phase distribution systems for ring‑network power supply and terminal power receiving. Xinhong Electrical solid insulated RMU main technical indexes are listed below for project reference:

  • Rated voltage: 12kV / 24kV
  • Rated frequency: 50Hz / 60Hz
  • Rated current: 630A, 1250A
  • Rated short‑time withstand current: 20kA‑31.5kA (1s‑4s)
  • Rated peak withstand current: 50kA‑80kA
  • Power frequency withstand voltage (phase‑to‑phase / phase‑to‑earth): 42kV‑65kV
  • Lightning impulse withstand voltage: 75kV‑125kV
  • Partial discharge value: ≤20pC
  • Mechanical operation life: ≥10 000 cycles
  • Protection grade: Live module IP67, cabinet shell IP4X

All above parameters follow IEC60076 and GB/T3906 standards. Xinhong Electrical supports parameter adjustment for high‑altitude, high‑pollution and special tropical‑climate projects according to client tender requirements.

2. Insulation Structure Design of Solid Insulated RMU

Different from air‑insulated RMU and traditional SF6 gas‑insulated ring main unit, solid insulated RMU adopts high‑performance epoxy resin as the main solid dielectric, combined with vacuum arc‑extinguishing technology, eliminating greenhouse‑gas leakage risk completely.

2.1 APG Automatic Pressure Gelation Casting Module

Xinhong Electrical solid insulated RMU uses mature APG (Automatic Pressure Gelation) casting process. Vacuum interrupter, main busbar, isolating switch, earthing switch and other high‑voltage live parts are integrally encapsulated inside epoxy resin solid modules. Semi‑conductive shielding layer is applied on module outer surface for reliable earthing, so operators cannot touch live parts directly even under operating conditions.

This integrated casting structure shortens phase‑to‑phase and phase‑to‑earth insulation distance, realizing compact cabinet size. It avoids hidden dangers caused by dust, moisture and condensation inside the cabinet, which frequently troubles air‑insulated switchgears.

2.2 Plug‑in Solid‑insulated Busbar Connection

Functional units (load‑switch unit, circuit‑breaker unit, fuse‑combination unit, PT unit) are connected via plug‑type fully‑insulated solid busbars. No exposed live conductors on connecting joints. Cabinet expansion can be completed on‑site without dismantling internal insulation components, greatly simplifying engineering installation work.

2.3 Cabinet Mechanical‑shield Compartment Layout

The metal cabinet divides operation mechanism room, instrument control room and solid‑insulated pole module into independent compartments with metal partition plates. When internal arc fault occurs, fault energy is limited inside single compartment, preventing fault spread across units. The cabinet reserves observation windows for visual checking of switch working status, and completes strict mechanical interlock to prevent mis‑operation risks.

3. Operation & Maintenance Adaptation Conditions for Solid Insulated Ring Main Unit

Though solid insulated RMU is well‑known for maintenance‑free features, it still has clear adaptation boundaries for site environment, installation and daily inspection. Xinhong Electrical summarizes practical O&M adaptation conditions accumulated from numerous domestic and overseas projects in China, Africa, Southeast Asia and Latin America.

3.1 Suitable Working Environment Conditions

✅ Applicable scenarios:

  • Ambient temperature:‑40℃ ~ +65℃
  • Altitude: ≤3000 m (custom‑enhanced version available for altitude up to 5000 m)
  • Heavy‑humid, salt‑fog coastal areas, high‑dust industrial zones, underground substations
  • Mining, new‑energy power station, urban ring‑network distribution projects

❌ Not suitable for long‑term working environment:

  • Environment with explosive flammable gas; strong corrosive gas eroding epoxy resin and metal parts
  • Severe continuous mechanical vibration without vibration‑damping transformation

3.2 On‑site Installation Requirements

  1. Keep cabinet mounting surface level; avoid long‑term sun exposure and rain‑soaking for non‑outdoor‑type models.
  2. Plug‑in busbar connectors shall be operated strictly following installation manual; avoid scratching epoxy module surface during assembly. Scratches on insulation surface may cause partial discharge increase.
  3. Complete reliable cabinet earthing according to drawing requirements; earthing resistance must meet local power‑grid standards.

3.3 Daily O&M Rules

  1. Normal‑condition maintenance‑free: Under qualified environment, solid insulated pole module requires no regular insulation maintenance, no gas pressure monitoring work, which is the biggest difference compared with SF6 ring main unit.
  2. Periodic visual inspection (1‑2 times per year): Check cabinet integrity, door sealing condition, operation mechanism flexibility, secondary‑loop wiring status. No need to open solid insulated pole modules.
  3. Fault handling principle: Once solid epoxy module suffers impact damage or internal insulation failure, whole‑module replacement is required; field partial repair for casting insulation is not recommended.
  4. Intelligent upgrade option: Xinhong Electrical can integrate partial‑discharge monitoring, temperature‑monitoring sensors for real‑time status early warning, supporting distribution‑network automation system docking.

4. Solid Insulated RMU vs SF6 Gas‑Insulated RMU: Practical Reference

Item Solid Insulated RMU (Xinhong Electrical) Traditional SF6 Gas‑Insulated RMU
Insulating medium Epoxy resin solid insulation + vacuum arc extinction SF6 gas
Greenhouse‑gas risk Zero SF6 High GWP greenhouse gas, leakage risk
Core‑module maintenance Maintenance‑free Regular gas pressure checking & leakage test
Anti‑humidity & anti‑pollution Excellent Good, depends on sealing performance
Fault repair mode Module replacement Gas recycling & partial‑component repair

5. Xinhong Electrical Solid Insulated RMU Project Support

As a China manufacturer of medium‑voltage solid insulated ring main unit, Xinhong Electrical provides full‑set solutions including type‑test documents, tender technical datasheets, installation guidance and after‑sales technical support. We support non‑standard customization for special voltage, current and environmental‑adaptation requirements for global EPC contractors, power utilities and industrial clients.

If you need technical datasheet, quotation or case reference of solid insulated ring main unit, feel free to contact our engineering team.