What is an oil immersed transformer?
An oil immersed transformer uses mineral insulating oil for both electrical insulation and heat dissipation. It is the most widely adopted distribution transformer for outdoor grid and heavy-load power projects. Xinhong Electrical produces S11, S13 series sealed oil immersed transformers at our Xuzhou factory. Our range covers 6kV–35kV, 100kVA to 25MVA, with pure copper winding as standard. All units comply with IEC standards and hold ISO, CE, CB certificates for global export and tender work.
Where are oil immersed transformers commonly used?
Oil immersed transformers are preferred for projects with large power demand, outdoor installation and tight budget control:
What technical specifications can we supply and customize?
| Item | Standard Options |
|---|---|
| Rated capacity | 100kVA, 250kVA, 500kVA, 800kVA, 1250kVA, 1600kVA, up to 25MVA |
| Voltage class | 6kV, 10kV, 20kV, 35kV |
| Model series | S11, S13 low-loss sealed type |
| Winding material | Pure copper winding (default), aluminum winding optional |
| Connection group | Dyn11, YNd11, Yyn0 |
| Cooling mode | ONAN (natural oil natural air), ONAF (forced air cooling) |
| Protection devices | Buchholz relay, oil level gauge, temperature indicator, pressure relief valve |
| Tank type | Fully sealed / conservator tank |
Custom support: special impedance, 60Hz frequency, coastal anti-corrosion paint, tropical heat adaptation, altitude derating and ester oil filling on request.
Why source oil immersed transformers directly from Xinhong factory in China?
We are a direct transformer manufacturer rather than a trading company. Our 27,000 m² production base has 15 years of transformer manufacturing experience.
Oil immersed transformer vs dry type transformer: which one fits your project?
Oil immersed transformer: Best for outdoor, large-capacity, cost-sensitive grid & solar projects. Better cooling, strong overload capacity, lower unit price. Requires oil containment and periodic oil maintenance. Dry type transformer: Best for indoor, populated, fire-restricted locations like subway, hospital and data center. No oil leakage risk, low maintenance, higher purchase cost.
EPC consultants usually select oil immersed transformers for remote outdoor substations and utility distribution networks.
What details do you need for an oil immersed transformer quotation?
Send us these parameters for accurate quotation and drawing:
Frequently Asked Questions
Q: Are S13 oil transformers more efficient than S11?
A: Yes. S13 series has lower no-load loss than S13, which cuts long-term grid operation energy consumption. S11 remains a cost-effective option for budget projects.
Q: What is a Buchholz relay used for?
A: Buchholz relay is a core protection accessory for oil immersed transformers. It detects gas accumulation and sudden oil surge inside the tank, sending alarm or trip signal for internal fault protection.
Q: How much maintenance does an oil immersed transformer need?
A: Periodic inspection is required: oil level check, leakage inspection, oil sampling & DGA testing every 1–3 years, gasket replacement when aging. With proper maintenance, service life can reach 30–40 years.
Q: Can oil immersed transformers be installed indoors?
A: It is allowed only if local fire codes permit, with oil spill containment pit, fire barrier and ventilation system prepared. Indoor projects normally choose dry type transformers instead.
Contact our engineering team to get your oil immersed transformer quotation and CAD drawing. Send your project specifications by email or WhatsApp.