Категории

Oil Immersed Power Transformer 100kVA-25MVA 35kV | Xinhong Electrical China

Xinhong Electrical manufactures 35kV oil immersed power transformers from 100kVA to 25MVA in China. Pure copper winding, ISO CE CB certified for power distribution projects. Contact us for quotations.
Sep 11th,2026 10 Взгляды

Oil Immersed Power Transformer 100kVA-25MVA | 35kV For Power Distribution – Xinhong Electrical


Introduction

Xinhong Electrical, a professional China manufacturer of power transformers, supplies high-performance 35kV oil immersed power transformer covering capacity range from 100kVA up to 25MVA for global power distribution applications. Built with pure copper windings and high-grade grain-oriented silicon steel core, our oil immersed transformers deliver low no-load loss, strong short-circuit resistance and stable long-time operation for utility grids, industrial plants, renewable energy stations and infrastructure projects.

Our factory has 15 years of manufacturing experience and holds ISO, CE and CB certifications. Every 35kV oil immersed power transformer undergoes strict factory testing before shipment, complying with IEC 60076 and GB national standards. We support custom voltage ratios, tap changers and accessories to match different project requirements worldwide.

Main Technical Parameters of Our 35kV Oil Immersed Power Transformer

  • Rated Capacity: 100kVA ~ 25MVA
  • Rated High Voltage: 35kV (customizable)
  • Cooling Type: ONAN / ONAF
  • Winding Material: Pure copper winding
  • Core: Cold rolled grain-oriented silicon steel sheet
  • Frequency: 50Hz / 60Hz optional
  • Standard: IEC 60076, GB 1094, ISO, CE, CB
  • Tap Changer: Off-circuit tap changer; on-load tap changer optional
  • Installation: Outdoor / indoor power distribution substation

Key Advantages of Xinhong Electrical Oil Immersed Transformer

  1. Low Energy Loss & Low Noise Adopting full diagonal seam stacking core structure, the transformer reduces iron loss and operating noise, helping customers cut long-term electricity operation cost.
  2. Strong Short Circuit Resistance Multi-layer cylindrical pure copper winding design improves mechanical strength and anti-shock performance, effectively protecting the transformer from sudden grid short-circuit faults.
  3. Vacuum Oil Injection Process Coils and iron core are fully vacuum dried, then vacuum oil filled. This removes moisture inside the transformer tank, extending service life and improving insulation reliability.
  4. Flexible Customization & Stable Lead Time As a China direct factory, Xinhong Electrical accepts non-standard specifications. We can adjust voltage combination, accessories, paint color and packaging according to client project drawings.
  5. Full Quality Inspection Each unit completes routine tests including ratio test, winding resistance, insulation test, no-load and load loss test before delivery. Test reports can be provided together with goods.

Application Scenarios

Our 35kV oil immersed power transformer 100kVA–25MVA is widely used in:

  • Urban and rural power grid distribution renovation
  • Industrial factory power supply
  • Solar and wind power station step-up / step-down systems
  • Mining, port, highway and large commercial complex power substations
  • Overseas power EPC projects

Why Buy Oil Immersed Power Transformer from Xinhong Electrical China?

Located in Jiangsu, China, Xinhong Electrical owns a 27,000㎡ transformer production base focusing on oil immersed transformers, dry type transformers and box-type substations. We are not a trading company but direct manufacturer, so we can offer competitive factory price and fast technical support.

We have rich export experience to Africa, Southeast Asia, Middle East, South America and other regions. Our engineering team can assist you with transformer selection, parameter confirmation and document preparation for customs and project approval. We also provide after-sales technical guidance for on-site installation and commissioning.

Get Your Quotation

If you are looking for a reliable China supplier of 35kV oil immersed power transformer from 100kVA to 25MVA, please send us your requirements including rated capacity, voltage ratio, cooling method and project location. Our sales engineer will reply with detailed quotation and technical datasheet within 24 hours.

Conclusion

The 35kV oil immersed power transformer from Xinhong Electrical is a cost-effective, certified power distribution solution ranging from 100kVA to 25MVA. With pure copper winding, low loss design and full factory testing, it serves as trusted power transformation equipment for global electrical projects. Contact Xinhong Electrical today to discuss your transformer project.